51 wrong, none detected, three replicas agreeing
A bad build on all three replicas at once agrees with itself. Mru Field 0.2.0 brings a new build in one slot at a time, checked by the old one.
Three replicas catch a fault in one of them. They cannot catch a fault in all
of them, and an update puts the same new build on all three at once. The demo
task has a bad build for this: --bug every@M flips one bit when the input’s
tick is a multiple of M, a bug only some inputs reach. With every@97 on all
three, 5,000 cycles gave 51 wrong outputs and detected=0 alive=3. All three
agreed, so the vote passed.
Field 0.2.0 stages it. The new build goes into slot 2 for a trial of
candidate_cycles, 1,000 by default, then slot 1, then slot 0. A
disagreement in a trial rejects it. In the second trial an output goes out
only if the slot still on the old build gave the same bytes, so two slots on
the new build cannot outvote it. That rule came from the bench. In an early
build, they could.
On an M4, 5,000 cycles a run. A build wrong from cycle 500: all at once, 4,501 wrong; staged, rejected at 500, zero wrong. A crash or a hang at 500: all at once, the run halts after 499 outputs; staged, rejected with three alive. Every@97, staged: “rejected 2 outvoted” on cycle 97. A build wrong from 2,500 is wrong 2,501 times either way. By then every slot has switched and nothing old is left to compare with. The spec says so.
The macOS runner found one more case. A power cut at checkpoint 200 landed
between a stuck fault and its retirement. On resume the stuck replica failed
its start-up known-answer test, so it was retired as startup, not strikes.
The checks now accept either label, still exactly once.
The supervisor did not change. The test had assumed the fault would be caught the way it was planned.